Takei, Hayanori
Isotope News, (779), p.11 - 15, 2022/02
The Japan Atomic Energy Agency (JAEA) has designed a Transmutation Physics Experimental Facility (TEF-P) as an experimental facility in the Japan Proton Accelerator Research Complex (J-PARC). The TEF-P is a critical assembly driven by a low-power proton beam, a maximum of 10 W, which is extracted from a high-power beam source, such as 250 kW of 400 MeV proton beam of the J-PARC Linac. To extract such a low-power proton beam from the high-power proton beam, we developed a laser charge exchange (LCE) device and employed its technique, which is one of the non-contact beam extraction techniques. For the proof of performance of the LCE device to the TEF-P, a low-power proton beam was extracted using a negative-hydrogen Linac having an energy of 3 MeV, and a bright laser. This paper summarizes the experimental results.